Heated THC and NMHC FID's with Permanent Back Purge Sample Filter
|
|
The
heated FID THC and NMHC analyzers described
in here are equipped with our permanent internal 2 micron stainless
sample filter. For cleaning and regenerating this filter compressed
air or nitrogen must be supplied applied for cleaning and
regeneration. Cleaning typically takes just a few seconds. Our
proprietary back purge feature not only cleans the internal sample
filter; When a sample line is attached between the sampling probe and
the analyzer, this line is automatically cleaned too with every back
purge process. In most cases, no probe filter is needed. Back purging
the sample filter can be automated with our available timing device.
Cleaning
the sample filter via back purge allows uninterrupted operation of
the FID analyzer during cleaning the sample filter.
|
Model
VE 7
Our
model VE7 heated FID is being manufactured since 1974 and is the
first heated THC analyzer ever built with a permanent back purge
sample filter. It is still the most liked heated FID throughout the
stack testing community due to its legendary ruggedness,
forgivingness and long standing accuracy and sensitivity. The VE7
belongs to the very first total hydrocarbon analyzers being
officially certified for compliance in Europe. In the USA, a
significant part of the Method 25A was written around the VE7. Many
thousand VE7s were sold mainly in Europe and in the USA.
TUV
approved and certified for 2. BImSchV. 13. BImSchV and 17. BImSchV,
QAL1 certified and fully complies with EN 12619, EN 13526 (EU) and
with EPA Method 25A and Method 503 (USA)
Features
- Maintenance
free sample filter back purge system allows filter to be cleaned
without dismantling (automatic timer optional)
- Built
in burner air generator, no external air cylinder needed
- All
components in contact with sample fully heated and controlled at
190 degree C
- Built-in
sample pressure and sample pumps
- Automatic
flame out alarm and contact
- Fast
response within 1 second
- Low
fuel consumption
- Very
selective
- Microprocessor
controlled PID-type temperature controller
- Remote
control for sample, calibrate and back purge is standard
- Remote
or automatic range change optional
Applications
- Stack
gas hydrocarbon emissions monitoring
- Fence
line monitoring
- Raw
exhaust vehicle emissions analysis
- Catalytic
converter testing
- Measuring
engine combustion efficiency
- Hydrocarbon
contamination monitoring in air and other gases
- Carbon
adsorption regeneration control
- Detection
of trace hydrocarbons in purity gases used in the semi conductor
industry
- LEL
monitor of solvent laden air
|
Model
3-200
Our
transportable model 3-200 fully heated FID is successfully used
throughout international markets for over 30 years. Also among
other portable gas FIDs, the 3-200 It is the first ever built
transportable fully heated FID using our proprietary back purge
sample filter. It is widely distributed throughout the industry and
the stack testing community and is much liked for its ruggedness, high accuracy,
sensitivity and stability. Our
optional 50 liter low pressure metal hydride fuel storage can easily
be mounted on the left side panel and allows a 45 hour minimum of
uninterrupted operation. This fuel storage can be self-refilled at a
low pressure of only 25 bar. No special adapter needed. A standard
2-stage pressure regulator with a 30 bar outlet is sufficient
The
3-200 is officially certified to be 100% identical to the VE7 and
3-300A analyzers. It is TUV approved and certified for 2. BImSchV.
13. BImSchV and 17. BImSchV and fully complies with EN 12619, EN
13526 (EU) and with EPA Method 25A and Method 503 (USA)
Features
- Maintenance
free sample filter back purge system allows filter to be cleaned
without dismantling (automatic optional)
- Built
in burner air generator, no external air cylinder needed
- All
components in contact with sample fully heated and controlled at
190 degree C
- Built-in
sample pressure and sample pumps
- Automatic
flame out alarm and contact
- Fast
response within 1 second
- Low
fuel consumption
- Very
selective
- Microprocessor
controlled PID-type temperature controller
- Remote
control for sample, calibrate and back purge is standard
- Remote
or automatic range change optional
Applications
- Stack
gas hydrocarbon emissions monitoring
- Fence
line monitoring
- Raw
exhaust vehicle emissions analysis
- Catalytic
converter testing
- Measuring
engine combustion efficiency
- Hydrocarbon
contamination monitoring in air and other gases
- Carbon
adsorption regeneration control
- Detection
of trace hydrocarbons in purity gases used in the semi conductor
industry
- LEL
monitor of solvent laden air
|
Model
3-300A
The
3-300A heated FID was designed in the early 80's as a space saving
alternative to our VE7. Also the 3-300A was a "first" in the
industry due to its sample filter back purge feature. It is also a very
much liked 19" rack mount heated FID throughout the stack
testing community and well known for its ruggedness, forgivingness
and long standing accuracy and sensitivity. The 3-300A is fully
identical to the VE7 and 3-200 and has been officially approved for that.
TÜV
approved and certified for 2. BImSchV. 13. BImSchV and 17. BImSchV
and fully complies with QAL1, EN 12619, EN 13526 (EU) and with EPA
Method 25A and Method 503 (USA)
Features
- Maintenance
free sample filter back purge system allows filter to be cleaned
without dismantling (automatic optional)
- Built
in burner air generator, no external air cylinder needed
- All
components in contact with sample fully heated and controlled at
190 degree C
- Built-in
sample pressure and sample pumps
- Automatic
flame out alarm and contact
- Fast
response within 1 second
- Low
fuel consumption
- Very
selective
- Microprocessor
controlled PID-type temperature controller
- Remote
control for sample, calibrate and back purge is standard
- Remote
or automatic range change optional
Applications
- Stack
gas hydrocarbon emissions monitoring
- Fence
line monitoring
- Raw
exhaust vehicle emissions analysis
- Catalytic
converter testing
- Measuring
engine combustion efficiency
- Hydrocarbon
contamination monitoring in air and other gases
- Carbon
adsorption regeneration control
- Detection
of trace hydrocarbons in purity gases used in the semi conductor
industry
- LEL
monitor of solvent laden air
|
Heated
Non Methane/ Methane/ Total Hydrocarbon FID Analyzer 109L
The
J.U.M 109A is being build since 1989. It is a heated FID analyzer to continuously and
simultaneously measure the Methane concentration, the Total
Hydrocarbon concentration and the Non Methane concentration simultaneously within a
gaseous sample. The 109A is a table top or 19-inch rack mount Heated
FID analyzer for the NMHC measurement in ambient air, exhaust gases
from a combustion process e.g. stack emissions, from any type of an
industrial vent, from an internal combustion engine, or from any
other emission containing hydrocarbons.
The
109A can be used as a table top or rack mount analyzer. It fully
complies with
EN 12619, EN 13526,
QAL 1 (EU), with 2. BImSchV, 13. BImSchV and 17. BImSchV, (Germany)
and with EPA Method 25A and Method 503 (USA).
-
All
critical components including pumps, sample filters, detectors and
main electronics are manufactured in house
-
Dual
detector/ dual electrometer design
-
Fully
heated to 190 degree C
-
Equipped
with zero and span gas inlets to be selected from internal selector
or from remote sources. Auto cal check optional
-
Typical
sensitivity 0.01 ppm CH4
-
21/2
digit LED display. Optional direct concentration display to read up
to 3 decade ranges without range change
-
Internal
sample pump and air pump
-
Internal
combustion air supply (No external air cylinder needed)
-
Very
low fuel consumption (less than 20 cc/min @ 100% H2)
-
Disposable
sample filter in rear panel
-
Automatic
ignite capability (optional)
-
Automatic
flame out alarm contact and fuel shut off
-
Sample
pressure regulator not in contact with sample gas
-
Multiple
range capability, 5 selectable ranges are standard
-
19"
rack mount unit, 221 mm high
Applications -
Optimization
of natural gas fired baking ovens and other furnaces
-
Gas
purifying system monitoring
-
Stack
gases (CEM) and all other Environmental and process applications
-
Air
and gas scrubber efficiency
-
Process
chemical gas analysis
-
Personnel
safety
-
Solvent
recovery
-
Catalytic
converter and thermal combustor testing
-
Automotive
catalyst and engine emissions
-
Fence